Frequency of Contact Lens Complications Between Contact Lens Wearers Using Multipurpose Solutions Versus Hydrogen Peroxide in the United States and Canada

Academic Article

Abstract

  • OBJECTIVES: To retrospectively compare frequency of contact lens (CL) complications in soft CL users of hydrogen peroxide (H2O2) and multipurpose solutions (MPS). METHODS: This was a multicenter, retrospective chart review of CL records from each patient's three most recent eye examinations at academic and private practices. Patients must have used the same solution type for at least 3 years. Univariate analyses were conducted using t tests, and chi-square or Fisher's exact test for categorical measures. RESULTS: There were 1,137 patients included, with 670 (59%) using MPS and 467 (41%) H2O2. In total, 706 (62%) experienced at least one complication; 409 used MPS and 297 used H2O2. There was no difference in the proportion of patients experiencing at least one complication between MPS (61%) and H2O2 (64%) (P=0.38). Multipurpose solutions users were more likely to report discomfort compared with H2O2 users (P=0.04). Presumed microbial keratitis was experienced by 16 MPS and nine H2O2 users (P=0.60). CONCLUSIONS: No significant differences were found in the frequency of CL complications between MPS and H2O2. H2O2 users were less likely to report discomfort and thus switching to a H2O2 system may be an alternative in CL users with discomfort.
  • Digital Object Identifier (doi)

    Author List

  • Tichenor AA; Cofield SS; Gann D; Elder M; Ng A; Walsh K; Jones LW; Nichols JJ
  • Start Page

  • 277
  • End Page

  • 282
  • Volume

  • 47
  • Issue

  • 5